Back to top
Send SMS Send Inquiry
Earthing Calculation for Switchyards and Substations Earthing Calculation for Switchyards and Substations Earthing Calculation for Switchyards and Substations Earthing Calculation for Switchyards and Substations Earthing Calculation for Switchyards and Substations Earthing Calculation for Switchyards and Substations
Earthing Calculation for Switchyards and Substations
Earthing Calculation for Switchyards and Substations Earthing Calculation for Switchyards and Substations Earthing Calculation for Switchyards and Substations Earthing Calculation for Switchyards and Substations Earthing Calculation for Switchyards and Substations

Earthing Calculation for Switchyards and Substations

Product Details:

  • Product Type Service
  • Material Delivered by email.
  • Measuring Voltage Range 765000 Volt (v)
  • Operating Temperature As per relevant IEC Celsius (oC)
  • Frequency (MHz) 50 or 60 Hertz (HZ)
  • Insulation Box NA
  • Protection System NA
  • Click to View more
X

Earthing Calculation for Switchyards and Substations Price And Quantity

  • 1 Number

Earthing Calculation for Switchyards and Substations Product Specifications

  • Delivery by email Kilograms (kg)
  • 50 or 60 Hertz (HZ)
  • NA
  • 765000 Volt (v)
  • As per relevant IEC Celsius (oC)
  • delivery by email Meter (m)
  • 12 months
  • Delivered by email.
  • A4
  • Service
  • NA
  • NA

Earthing Calculation for Switchyards and Substations Trade Information

  • Delivery by email
  • Cash Against Delivery (CAD) Cash Advance (CA) Cash in Advance (CID) Cheque Days after Acceptance (DA) Telegraphic Transfer (T/T)
  • 3 Number Per Week
  • 1 Week
  • Yes
  • Free samples are available
  • Asia Australia North America Eastern Europe Middle East Africa
  • All India
  • ISO 9001, 2015

Product Description

The object of a good grounding system is to provide under and around the site a surface which shall be at a uniform potential and be as near zero or absolute earth potential as possible. This is to ensure that no human being in the vicinity is subject to shock or injury on the occurrence of short circuit or of development of other abnormal condition in the equipment. The basic design criteria of a properly designed gounding system are meant to :


1. Stabilize circuit potential with respect to ground and limit the overall potential rise.

2. Protect life and property from over-voltage.

3. Provide low impedance path to fault currents to ensure prompt and  consistent operation of protective devices during ground faults.

4. Keep maximum voltage gradient along the surface inside and around the plant site within safe limits during ground faults.

While carrying out the earthing calculation, we check the following :

a. Calculated step potential is below the tolerable value.

b. Calculated touch potential is below the tolerable value.

c. Ground system resistance is below 1 ohm.

d. Ground potential rise is limited to 5kV or so.

We can deliver earthing calculations and layout drawings with BOQ as per IEEE 80 or CBIP manual or IS 3043. 